Production Schedule > Aeratör
AERATOR
Aerators are used all kinds of wastewater treatment plants, aerobic stabilization pools, water sources such as pools and lagoons etc. for aeration and mixing.
The oxygen transfer output of the aerators selected based on the depth and dimensions of the basin at 20 C is within 1.2-1.8 kgO2/kWh range.
In aerators manufactured with various capacities from 1.5 kW to 132 kW,
STANDARD SPECIFICATIONS
"Flander mark redactor,
"
Body covered with St37+ epoxy,
"
Floating construction consists of 3 floating bridge covered with St 37 + epoxy mounted on a 3-arm floating mechanism
.
"
Perpendicular shaft is manufactured as covered with St 37 +epoxy and can also be manufactured as made of AISI304 or 316 stainless steel,
"
The effective depth of the aerator will be increased by extending suction cone.
|
| TYPE |
POWER
kW
|
FAN CYCLE
Cycle/min.
|
EFFECTIVE DEPTH
|
OXYGEN OUTPUT
Kg/ hour
|
FLOATING
TYPE
OUTER
DIAMETER
(m) |
| ÖA1.5 |
1.5 |
95 |
|
2.7 |
5.10 |
| ÖA2.2 |
2.2 |
85 |
|
3.9 |
5.20 |
| ÖA3 |
3 |
95 |
|
5.4 |
5.20 |
| ÖA4 |
4 |
110 |
|
7.2 |
5.60 |
| ÖA5.5 |
5.5 |
90 |
|
9.9 |
6.00 |
| ÖA7.5 |
7.5 |
100 |
|
13.5 |
6.00 |
| ÖA11 |
11 |
95 |
|
19.8 |
6.50 |
| ÖA15 |
15 |
85 |
|
27 |
6.50 |
| ÖA18.5 |
18.5 |
70 |
|
33.3 |
7.40 |
| ÖA22 |
22 |
60 |
|
39.6 |
7.70 |
| ÖA30 |
30 |
65 |
|
54 |
7.70 |
| ÖA37 |
37 |
45 |
|
66.6 |
8.50 |
| ÖA45 |
45 |
40 |
|
81 |
8.50 |
| ÖA55 |
55 |
45 |
|
99 |
8.80 |
| ÖA75 |
75 |
35 |
|
135 |
9.35 |
| ÖA90 |
90 |
30 |
|
166 |
10.10 |
| ÖA110 |
110 |
25 |
|
198 |
10.50 |
| ÖA132 |
132 |
27 |
|
237 |
10.50 |
|
|